{"title":"Oxygen Sensors","description":null,"products":[{"product_id":"divesoft-oxygen-sensor-r22s","title":"Oxygen Sensor R22S (Molex 3-Pin)","description":"\u003cp dir=\"ltr\"\u003e\u003cspan\u003eThe Divesoft R22S is a galvanic oxygen sensor made for gas analyzers. It is the standard replacement sensor for the Divesoft DNA, SOLO O2, SOLO, ECHO and He\/O2, and it works in other analyzers built for a Molex 3-pin R22-type cell, such as the Apeks DSX analyzer accessory, Cochran Lifeguard, DiveTek Oz, DiveNav cootwo, Mares EANx and OxySpy. The R22S has no hydrophobic membrane and is not suitable for rebreathers. For closed circuit use, choose the Divesoft R22D or the Narked at 90 NaNM01.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp dir=\"ltr\"\u003e\u003cmeta charset=\"UTF-8\"\u003e\u003cspan\u003eMolex 3-pin connector, M16x1 thread. Measuring range 0 to 100% oxygen, accuracy ±1% of full scale at constant temperature and pressure.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp dir=\"ltr\"\u003eDivesoft rates the expected service life at up to three years in air under normal conditions. In regular use, plan on replacing the sensor every 12 to 24 months, or sooner if it no longer calibrates reliably. Keep unused sensors unopened, ideally refrigerated, until you install them.\u003c\/p\u003e\n\u003cp dir=\"ltr\"\u003eGalvanic oxygen sensors start aging on the day they are made, in storage as well as in use, so we list the manufacturing date of every sensor we sell. You will find it in the selector above.\u003c\/p\u003e\n\u003cp dir=\"ltr\"\u003eEach sensor is registered under its own serial number and carries a 12-month limited warranty from Divesoft from the date of sale.\u003c\/p\u003e\n\u003c!----\u003e","brand":"Divesoft","offers":[{"title":"2026-06","offer_id":48197502107813,"sku":"3011-2026-06","price":385.0,"currency_code":"AED","in_stock":true},{"title":"2026-03","offer_id":48181507031205,"sku":"3001-2026-03","price":350.0,"currency_code":"AED","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0440\/6883\/1397\/files\/Divesoft-Oxygen-Sensor-22D.jpg?v=1723193835"},{"product_id":"divesoft-oxygen-sensor-r22d","title":"Oxygen Sensor R22D (Molex 3-Pin)","description":"\u003cp dir=\"ltr\"\u003eThe Divesoft R22D is a galvanic oxygen sensor made for rebreathers. Its hydrophobic membrane protects the cell from the moisture in a breathing loop, which is what makes it suitable for closed circuit use. It is the sensor type specified for the Divesoft Liberty, and it also works in Divesoft analyzers and in other rebreathers and analyzers built for a Molex 3-pin R22D-type cell. Always confirm the cell is approved by your unit manufacturer before installing it.\u003c\/p\u003e\n\u003cp dir=\"ltr\"\u003eMolex 3-pin connector, M16x1 thread. Measuring range 0 to 100% oxygen, accuracy ±1% of full scale at constant temperature and pressure. A new cell delivers 7 to 13 mV in air at 25°C and sea level.\u003c\/p\u003e\n\u003cp dir=\"ltr\"\u003eDivesoft rates the service life in a rebreather at one to two years depending on use, storage and humidity. Follow the replacement schedule set by your unit manufacturer and training agency, and replace any cell that fails calibration, reads unstable or becomes current limited. Keep unused sensors unopened, ideally refrigerated, until you install them.\u003c\/p\u003e\n\u003cp dir=\"ltr\"\u003eGalvanic oxygen sensors start aging on the day they are made, in storage as well as in use, so we list the manufacturing date of every sensor we sell. You will find it in the selector above.\u003c\/p\u003e\n\u003cp dir=\"ltr\"\u003eEach sensor is registered under its own serial number and carries a 12-month limited warranty from Divesoft from the date of sale.\u003c\/p\u003e\n\u003c!----\u003e","brand":"Divesoft","offers":[{"title":"2026-08","offer_id":48197504139429,"sku":"3092-2026-08","price":410.0,"currency_code":"AED","in_stock":true},{"title":"2024-10","offer_id":48181590786213,"sku":"3092-2024-10","price":250.0,"currency_code":"AED","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0440\/6883\/1397\/files\/Divesoft-Oxygen-Sensor-22S.jpg?v=1723188533"},{"product_id":"oxygen-sensor-adapter-jj-ccr-to-molex","title":"Oxygen Sensor Adapter, JJ-CCR to Molex","description":"\u003ch2\u003eCoax Female to Molex Female Adapter\u003c\/h2\u003e\n\u003cp\u003eThis versatile female-to-female adapter is designed to convert cell types for the JJ-CCR.\u003c\/p\u003e\n\u003cp\u003eA must-have backup for your kit, it allows you to switch to an alternative sensor type seamlessly in case a JJ cell fails, ensuring uninterrupted performance.\u003c\/p\u003e\n\u003cp\u003eChoose from cable lengths of 16 cm or 27 cm to suit your setup. Reliable, compact, and essential for divers seeking flexibility and peace of mind.\u003c\/p\u003e\n\u003c!----\u003e","brand":"Narked at 90","offers":[{"title":"16 cm","offer_id":44551601324197,"sku":"CTOM","price":220.0,"currency_code":"AED","in_stock":true},{"title":"27 cm","offer_id":44551601356965,"sku":"CTOM-270","price":220.0,"currency_code":"AED","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0440\/6883\/1397\/files\/Oxygen-Sensor-Adapter_-JJ-CCR-to-Molex.jpg?v=1734684267"},{"product_id":"narked-at-90-oxygen-sensor-nanm01-molex-3-pin","title":"Oxygen Sensor NaNM01 (Molex 3-Pin)","description":"\u003cp dir=\"ltr\"\u003e\u003cspan\u003eThe Narked at 90 NaNM01 is a galvanic oxygen sensor made for rebreathers. It is the cell Narked at 90 specifies for its own Apoc pod and Deep Pursuit head, and it works in other rebreathers and analyzers built for a Molex 3-pin R22D-type cell, such as KISS and Prism 2 units and Molex-connector analyzers. Not for use in Poseidon rebreathers. For the Divesoft Liberty, use the Divesoft R22D. Always confirm the cell is approved by your unit manufacturer before installing it.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp dir=\"ltr\"\u003eGold plated Molex 3-pin connector. Manufactured to Narked at 90's specification, with improved response time and temperature compensation.\u003c\/p\u003e\n\u003cp dir=\"ltr\"\u003eNarked at 90 rates the shelf life at two years from the manufacturing date in the sealed bag. Follow the replacement schedule set by your unit manufacturer and training agency, and replace any cell that fails calibration, reads unstable or becomes current limited. Keep unused sensors in their sealed bag until you install them.\u003c\/p\u003e\n\u003cp dir=\"ltr\"\u003eGalvanic oxygen sensors start aging on the day they are made, in storage as well as in use, so we list the manufacturing date of every sensor we sell. You will find it in the selector above.\u003c\/p\u003e\n\u003cp dir=\"ltr\"\u003eThe sensor carries a 12-month warranty from Narked at 90 from the invoice date.\u003c\/p\u003e\n\u003c!----\u003e","brand":"Narked at 90","offers":[{"title":"2025-10","offer_id":48181477834917,"sku":"NaNM01-2025-10","price":400.0,"currency_code":"AED","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0440\/6883\/1397\/files\/1.jpg?v=1761896223"},{"product_id":"jj-ccr-oxygen-sensor-r17jj-ccr","title":"Oxygen Sensor R17JJ-CCR (Coax)","description":"\u003cp dir=\"ltr\"\u003eThis is an original JJ-CCR oxygen sensor, type R17JJ-CCR, approved for use in the JJ-CCR rebreather. It fits the newer type of head with the connectors on the head. Accurate oxygen monitoring is essential for safe rebreather operation, and these cells provide reliable real-time PPO2 readings to the JJ-CCR controller and HUD throughout the dive. JJ-CCR authorizes only this sensor type; cells marked PSR-11-39-JJ are not factory authorized. The unit uses three sensors, sold here individually. For other rebreathers, see the Divesoft R22D and the Narked at 90 NaNM01.\u003c\/p\u003e\n\u003cp dir=\"ltr\"\u003eCoax connector on an attached cable, supplied in a sealed bag.\u003c\/p\u003e\n\u003cp dir=\"ltr\"\u003eJJ-CCR sets stricter limits for this cell than the generic life of galvanic sensors: maximum sensor life is 15 months from the date of manufacture, of which a maximum of 12 months of use in the rebreather. Packaging time beyond three months is deducted from the 12 months of use. Replace all three cells at least every 12 months, and replace any cell that fails calibration or reads unstable. Keep unused sensors in their sealed bag until you install them.\u003c\/p\u003e\n\u003cp dir=\"ltr\"\u003eGalvanic oxygen sensors start aging on the day they are made, in storage as well as in use, so we list the manufacturing date of every sensor we sell. You will find it in the selector above.\u003c\/p\u003e\n\u003c!----\u003e","brand":"JJ-CCR","offers":[{"title":"2026-09","offer_id":50551128785061,"sku":"R17JJ-CCR-2609","price":500.0,"currency_code":"AED","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0440\/6883\/1397\/files\/JJ-CCROxygenSensorR17JJ-CCR.jpg?v=1790767090"}],"url":"https:\/\/titandiveshop.com\/collections\/oxygen-sensors.oembed","provider":"TITAN DIVE SHOP","version":"1.0","type":"link"}